H. Lybecker et T. Andersen, REPETITIVE HEARING-LOSS FOLLOWING DURAL PUNCTURE TREATED WITH AUTOLOGOUS EPIDURAL BLOOD PATCH, Acta anaesthesiologica Scandinavica, 39(7), 1995, pp. 987-989
A case of repetitive hearing loss following an otherwise uncomplicated
diagnostic dural puncture is presented. The patient developed severe
postdural puncture headache (PDPH) and three episodes of pronounced ve
stibulocochlear disturbances within five weeks after only one dural pu
ncture. On all three occasions the headache and the associated symptom
s were treated with an autologous epidural blood patch (LEBP) resultin
g in the immediate disappearance of all the subjective complaints of p
ostdural puncture headache and the normalization of an audiological te
st within minutes.