DETERMINATION OF ORGANIC ADDITIVES IN COPPER PLATING ELECTROLYTES BY CYCLIC VOLTAMMETRY

Citation
Ap. Rysev et Ms. Igumnov, DETERMINATION OF ORGANIC ADDITIVES IN COPPER PLATING ELECTROLYTES BY CYCLIC VOLTAMMETRY, Industrial laboratory, 61(1), 1995, pp. 1-4
Citations number
10
Categorie Soggetti
Materials Science, Characterization & Testing","Instument & Instrumentation
Journal title
ISSN journal
00198447
Volume
61
Issue
1
Year of publication
1995
Pages
1 - 4
Database
ISI
SICI code
0019-8447(1995)61:1<1:DOOAIC>2.0.ZU;2-K
Abstract
A cyclic voltammetry method for simultaneous determination of OS-20 an d BESM (a brightener for sulfuric acid copper plating electrolyte) org anic additives has been developed. Within the concentration range of 0 .1 - 0.4 g/liter, the relative standard deviation does not exceed 0.11 .