A QUALIFICATION TEST FOR RELAY CONTACTS AS ISOLATION DEVICES IN NUCLEAR-POWER-PLANTS

Citation
Ce. Beck et al., A QUALIFICATION TEST FOR RELAY CONTACTS AS ISOLATION DEVICES IN NUCLEAR-POWER-PLANTS, IEEE transactions on nuclear science, 42(5), 1995, pp. 1467-1473
Citations number
5
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
42
Issue
5
Year of publication
1995
Pages
1467 - 1473
Database
ISI
SICI code
0018-9499(1995)42:5<1467:AQTFRC>2.0.ZU;2-2
Abstract
A methodology is introduced for testing the integrity of relay contact s as isolation devices in Class IE circuits, A design activity that in stalled a new relay established the need for a new type of qualificati on test, This paper describes the process of establishing the test met hodology, the development of the test plan, and the results of testing , It also describes the limitations of applying the results of any spe cific test to actual field installations, and offers other potential u ses of the methodology.