Rd. Godoy et al., REACTION HEAT MEASUREMENTS IN THE ENZYMATIC-HYDROLYSIS REACTION OF PENICILLIN GK TO OBTAIN 6-APA, Enzyme and microbial technology, 19(8), 1996, pp. 585-589
The purpose of this study was to measure heats involved in the hydroly
sis process for the industrial production of 6-aminopenicillanic acid
(6-APA) using dynamic calorimetry techniques. The experimental design
was planned using Hess' law The information derived from the calorimet
er was correlated mathematically to determine the heat released during
enzymatic hydrolysis. This is important for temperature control syste
ms and reactor design. The results obtained with the calorimetric meas
urements at 308 K and pH 7.5 are the penicillin hydrolysis, Delta H-hy
drol, at 35.9 +/- 5.7 W mol(-1) and phenyl acetic acid neutralization,
Delta H-neut, at -47.1 +/- 3.8 kJ mol(-1). (C) 1996 by Elsevier Scien
ce Inc.