A containerless electromagnetic levitator has been now constructed for
precise measurement of the thermophysical properties of molten silico
n in the 10s Japan Microgravity Center (JAMIC) drop shaft. Precise con
trol of the levitated sample position from normal gravity to micrograv
ity was aimed and a compact electromagnetic levitator for demonstratin
g the control technology at the gravity transition point was tested at
the 1.3s HNIRI (Hokkaido National Industrial Research Institute) drop
tower. The oscillation generated at the transition was completely eli
minated with current control of electromagnetic coil.