Ps. Tofts et al., MR MAGNETIZATION-TRANSFER MEASUREMENTS IN TEMPORAL-LOBE EPILEPSY - A PRELIMINARY-STUDY, American journal of neuroradiology, 16(9), 1995, pp. 1862-1863
Citations number
4
Categorie Soggetti
Neurosciences,"Radiology,Nuclear Medicine & Medical Imaging
MR magnetization transfer ratio was measured in both hippocampi of thr
ee patients with temporal lobe epilepsy, and in two control subjects.
The magnetization transfer ratio in each section was significantly low
er on the affected side than on the contralateral side and in control
subjects. Magnetization transfer ratio measurements are relatively fas
t and precise; this preliminary study shows that they may provide usef
ul presurgical information.