Li. Elizarov et al., MEASUREMENT OF H- ION DENSITY BY LASER PHOTODETACHMENT IN A CESIUM-HYDROGEN PLASMA, Review of scientific instruments, 66(10), 1995, pp. 4925-4927
The standard photodetachment method was applied for the diagnostic of
negative ions in a cesium-hydrogen plasma. The plasma generator studie
d is a steady-state source of hydrogen negative ions with a cesium hol
low cathode and a radial magnetic field. We demonstrate the possibilit
y of using the photodetachment method for the diagnostics of cesium-hy
drogen plasma. (C) 1995 American Institute of Physics.