A Monte Carlo facility has been developed for modelling the response o
f semiconductor devices to mixed neutron-photon fields. This utilises
the code MCNP for neutron and photon transport and a new code, STRUGGL
E, which has been developed to model the secondary charged particle tr
ansport. It is thus possible to predict the pulse height distribution
expected from prototype electronic personal detectors, given the detec
tor efficiency factor. Initial calculations have been performed on a s
imple passivated implanted planar silicon detector. This device has al
so been irradiated in neutron, gamma and X ray fields to verify the ac
curacy of the predictions. Good agreement was found between experiment
and calculation.