K. Takamura et al., DETERMINATION OF BARNIDIPINE IN HUMAN SERUM AND DOG PLASMA BY HPLC WITH ELECTROCHEMICAL DETECTION, Biological & pharmaceutical bulletin, 18(10), 1995, pp. 1311-1314
Barnidipine is a 1,4-dihydropyridine calcium antagonist. HPLC was cond
ucted on a polybutadiene coated alumina column using an alkaline mobil
e phase and an electrochemical detector to determine the content of th
is drug in serum and plasma. A good linear relationship between barnid
ipine concentration and peak height was found in 5-500 ng/ml with a co
rrelation coefficient of 0.998. The detection limit was 1 ng/ml. The w
ithin-day and day-to-day variations were examined for control human se
rum. Relative standard deviation of within-day assay for serum spiked
with 10 ng/ml barnidipine HCl was 6.9% and the recovery was 104%. A ph
armacokinetic study was made in which the time course of barnidipine i
n dog plasma was followed.