Detailed analysis of systematic errors in measurements of Lamb-shift i
n hydrogen by the atomic interferometer method is presented. Quantum-e
lectrodynamic calculations of the 2P-level decay constant are describe
d in Appendix I. The experimental results are compared with high-preci
sion theoretical calculation data.