DEVELOPMENT AND TESTS OF EXTRUDED ETHYLENEPROPYLENE-RUBBER-INSULATED SUPERCONDUCTING CABLE
Citation
M. Kosaki et al., DEVELOPMENT AND TESTS OF EXTRUDED ETHYLENEPROPYLENE-RUBBER-INSULATED SUPERCONDUCTING CABLE, Cryogenics, 35(11), 1995, pp. 805-807
Categorie Soggetti
Physics, Applied",Thermodynamics
SICI code
0011-2275(1995)35:11<805:DATOEE>2.0.ZU;2-B
Abstract
The simultaneous application of the design voltage (20 kVrms) and curr
ent (2 kArms) to ethylenepropylene-rubber (EPR)-insulated superconduct
ing cable, cooled by liquid helium, was successfully carried out. The
superconductor was a niobium layer clad on a copper pipe. The EPR insu
lation was extruded simultaneously with semiconducting electrostatic s
hielding layers. A specific advantage of this cable design is the comp
lete exclusion of the cryogenic helium from the electrical Insulation
structure.