M. Budzanowski et B. Burgkhardt, THIN (LIF)-LI-6 7-MG,CU,P AND (LIF)-LI-6/7-MG,TI DETECTORS FOR AUTOMATIC ALBEDO NEUTRON DOSIMETRY/, Radiation measurements, 24(4), 1995, pp. 445-448
Sintered pairs of MTS-6s, MTS-7s is ((LiF)-Li-6/7:Mg,Ti) two-layer and
0.04 cm thick MTS-6t, and MTS-7t detectors for personal or environmen
tal albedo dosimetry in mixed neutron-gamma fields, were developed and
manufactured at the Institute of Nuclear Physics (INP) in Krakow, Pol
and (commercially available from TLD Niewiadomski & Co., Krakow, Polan
d). The dosimetric properties of these detectors were compared with th
ose of standard 0.09 cm thick TLD-600/TLD-700 pairs and with highly se
nsitive 0.05 cm thick GR-206 and GR-207 ((LiF)-Li-6/7:Mg,Cu,P), both a
vailable from Bicron Harshaw (BH). The relative neutron-to-gamma respo
nse ratio, R(n7), for MTS-6s and MTS-6t detectors irradiated by modera
ted neutrons from a Cf-252 source and by Cs-137 photons and read out w
ith the Automatic Alnor Dosacus system, is about 2 times higher than t
hat of standard 0.09 cm thick TLD-600 chips. The relative photon respo
nses, R(i), of highly sensitive GR-206 and GR-207 detectors was about
5 times higher than that of TLD-600, but due to the lower sensitivity
of the (LiF)-Li-6:Mg,Cu,P material to high LET radiations, the respect
ive value of R(n7) was only 0.45.