SENSITIVE MEASUREMENT OF PHASE-SHIFTS DUE TO THE AC STARK-EFFECT IN ACA OPTICAL RAMSEY INTERFEROMETER

Citation
A. Morinaga et al., SENSITIVE MEASUREMENT OF PHASE-SHIFTS DUE TO THE AC STARK-EFFECT IN ACA OPTICAL RAMSEY INTERFEROMETER, Physical review. A, 48(2), 1993, pp. 1364-1368
Citations number
17
Categorie Soggetti
Physics
Journal title
ISSN journal
10502947
Volume
48
Issue
2
Year of publication
1993
Pages
1364 - 1368
Database
ISI
SICI code
1050-2947(1993)48:2<1364:SMOPDT>2.0.ZU;2-1
Abstract
We constructed an optical Ramsey atomic interferometer, which has a re solution of 8 fm for the difference between arms of the interferometer , and used it to examine the phase shift due to the ac Stark effect of the excited state of the intercombination line (S-1(0)-P-3(1)) of Ca. It was clearly observed that the phase shift is in proportion to the field power and in inverse proportion to the detuning frequency of the laser. The proportionality coefficient obtained was in good agreement with the theoretical one.