EXPERIENCE WITH THE AO FEMORAL INTERLOCKI NG NAIL FOR TREATMENT OF THE FRACTURED FEMORAL-SHAFT

Citation
D. Schafer et al., EXPERIENCE WITH THE AO FEMORAL INTERLOCKI NG NAIL FOR TREATMENT OF THE FRACTURED FEMORAL-SHAFT, Helvetica chirurgica acta, 60(1-2), 1993, pp. 231-234
Citations number
NO
Categorie Soggetti
Surgery
Journal title
ISSN journal
00180181
Volume
60
Issue
1-2
Year of publication
1993
Pages
231 - 234
Database
ISI
SICI code
0018-0181(1993)60:1-2<231:EWTAFI>2.0.ZU;2-X
Abstract
57 fractures of the femoral shaft, treated with an AO femoral interloc king nail, have been analysed in a retrospective study. 40 nails have been implanted primarily, 17 as secondary procedures following differe nt operations. In the group of primary nailing 35/40 reached a good or very good result, 8 of them however, following secondary operations. In the group of the secondary nailing, 9/17 patients had a good or a v ery good result. 3 pseudarthroses persisted. The AO femoral interlocki ng nail therefore appears to be an adequate implant for the treatment of femoral shaft fractures, but a precise implantation technique is a prerequisite for the successful outcome.