Bn. Dobson et al., INSTRUMENT FOR MEASURING BIND STRENGTH OF RESTRUCTURED AND EMULSION-TYPE MEAT-PRODUCTS, Journal of texture studies, 24(3), 1993, pp. 303-310
A sensitive and inexpensive penetrometer is described, consisting of a
mounted rod and polished steel ball that may be advanced downward at
variable speed through meat slices mounted on a plexiglass cylinder. T
he slice + mounting cylinder was placed on a top-loading balance, tare
d to zero, and centered under the penetrometer rod. Bind strength was
measured as the peak force (g) required for the steel ball advancing a
t 2.0 cm/min to penetrate the meat slice. Data points (grams force ver
sus time) were collected and plotted using an IBM-compatible personal
computer and printer. Since the balance collected gram values continuo
usly, a QuickBasic program was developed, allowing the user to specify
the time interval (1, 2, 5 s, etc.) between recorded values. Bind str
ength of turkey rolls was increased by finely chopping the emulsion (v
s. coarsely-ground samples), and by inclusion of 3 % nonfat dry milk.
Whey protein concentrate (3 %) increased bind strength of finely chopp
ed, but not coarsely ground rolls.