Jh. Lai et Ae. Johnson, MEASURING POLYMERIZATION SHRINKAGE OF PHOTO-ACTIVATED RESTORATIVE MATERIALS BY A WATER-FILLED DILATOMETER, Dental materials, 9(2), 1993, pp. 139-143
A water-filled dilatometer specifically designed for determining the p
olymerization shrinkage of photo-activated composite restorative mater
ials was used to measure the polymerization shrinkage of three visible
light-activated composites. Polymerization shrinkage values ranged fr
om 1.82% for P-50 to 2.15% and 2.19% for Herculite XRV and Prisma APH,
respectively. Shrinkage data obtained in this investigation were comp
ared with the published data, and the factors which affect shrinkage m
easurements were reviewed. It was concluded that maintaining a constan
t temperature environment (+/- 0.02-degrees-C) for the dilatometer dur
ing the shrinkage test was the most critical factor for successful app
lication of the dilatometer.