G. Aly et al., APPLICATION OF ABSORPTION HEAT TRANSFORMERS FOR ENERGY-CONSERVATION IN THE OLEOCHEMICAL INDUSTRY, International journal of energy research, 17(7), 1993, pp. 571-582
Citations number
NO
Categorie Soggetti
Energy & Fuels",Engineering,"Nuclear Sciences & Tecnology
A comprehensive energy mapping of an oleochemical plant, for productio
n of technical fatty acids and refined glycerol, was performed. Satura
ted water vapour is currently produced at 100-degrees-C from four flas
h vessels used to depressurize condensate streams emerging from differ
ent processing units in the plant. This vapour has a heat content of 3
14 kW and is currently condensed in a dump condenser and discharged. I
ncorporating an absorption heat transformer system would enable the re
covery of almost half of this energy and a temperature lift of 34-degr
ees-C can be achieved. The heat transformer system delivers steam at 3
bar which can be fully reused in the plant. An economic analysis resu
lted in a pay-off period of less than 18 months based on a steam cost
of 14.25 $/GJ, an installed equipment cost of 535 $/kW, an annual oper
ation time of 7200 h, and a heat transformer efficiency of 0.45. Howev
er, the pay-off period depends on the estimated steam cost and heat tr
ansformer efficiency, and also on how much of the existing equipment c
an be utilized as components in the heat transformer. Installing the h
eat transformer would require minimum changes in the existing plant.