Cg. Panchal et al., EVALUATION OF RESOLVING POWER OF A NEUTRON RADIOSCOPY SYSTEM FROM EDGE RESPONSE FUNCTION MEASUREMENTS, Insight, 39(2), 1997, pp. 97-99
In the present study, we have attempted to estimate the resolving powe
r of a small-scale neutron radioscopy system, which is being rip-grade
d In radioscopic images unsharpness is an important factor characteris
ing the image quality; this has been estimated from the digital image
of a physically sharp edge object. An edge response function so obtain
ed has been used to determine the spatial resolution in terms of a lin
e spread function and a modulation transfer function. The results of i
nitial experiments have provided a quantitative measure of resolution.
A procedure for measurement of these transfer functions and a method
to confirm accuracy of measurements using simple test objects are repo
rted in this paper.