Dds. Collie et al., LUNG COMPLIANCE, LUNG-VOLUME AND TRANSFER-FACTOR FOR CARBON-MONOXIDE IN ANESTHETIZED SHEEP - NORMAL VALUES AND REPRODUCIBILITY OF MEASUREMENTS, Research in Veterinary Science, 55(2), 1993, pp. 137-143
Measurements of quasistatic compliance (C(qst)), effective alveolar vo
lume (V(A,eff)) and single-breath transfer factor for carbon monoxide
(T(L,CO, 'sb')) were completed in 16 normal, anaesthetised, adult Texe
l ewes. Regression equations were computed for these variables as a fu
nction of bodyweight and the optimal equations selected. The 95 per ce
nt prediction intervals for the equations were calculated such that no
rmal lung function in similar sheep could be accurately predicted. The
long term reproducibility of these measurements was assessed in nine
sheep, measured at monthly intervals over a period of five months. Alt
hough measurements made in individual sheep were often highly variable
, the variation between repeated measurements on the separate days for
the group was insignificant.