DETERMINATION OF METHYLCYCLOPENTADIENYLMANGANESE TRICARBONYL (MMT) INGASOLINE AND ENVIRONMENTAL-SAMPLES BY GAS-CHROMATOGRAPHY WITH HELIUM MICROWAVE PLASMA-ATOMIC EMISSION DETECTION
Yk. Chau et al., DETERMINATION OF METHYLCYCLOPENTADIENYLMANGANESE TRICARBONYL (MMT) INGASOLINE AND ENVIRONMENTAL-SAMPLES BY GAS-CHROMATOGRAPHY WITH HELIUM MICROWAVE PLASMA-ATOMIC EMISSION DETECTION, Applied organometallic chemistry, 11(1), 1997, pp. 31-37
A highly sensitive and specific method is described for the determinat
ion of methylcyclopentadienylmanganese tricarbonyl (MMT) in gasoline a
nd environmental samples by gas chromatography-plasma atomic emission
detection (GC-AED). The procedure is simple, rapid and free from inter
ferences, The absolute limit of detection is 0.5 fg of MMT (0.5 x 10(-
15) g) expressed as Mn. The precision for replicate injections (n=5) o
f an MMT solution (10 pg Mn) was 2.8% relative standard deviation (RSD
). Applications of the method to analysis of gasoline (petrol), and pr
eliminary results of the analyses of environmental samples such as air
and roadside dirt, are given. (C) 1997 by John Wiley & Sons, Ltd.