B. Mrosek et al., COMPUTER-ASSISTED VOICE RECOGNITION FOR R ADIOLOGICAL REPORTING, RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren, 159(5), 1993, pp. 481-483
A voice recognition system, called Tangora, has been designed for the
German language; its prototype has been tested to assess its clinical
usefulness for radiological reporting. Its technical vocabulary consis
ts of 20,000 words. The system recognises words spoken provided short
pauses are inserted. The Tangora system was compared with conventional
methods of dictation, using 68 radiological reports. The work necessa
ry for each system was analysed. The average time taken by the Tangora
system per report was 671 seconds compared with 182 seconds for conve
ntional dictation but improvements in the speed of the new system for
radiological reporting is to be expected.