J. Alpizar et al., SIMULTANEOUS DETERMINATION OF CHLORIDE AND FLUORIDE IONS IN WATERS BYSEQUENTIAL INJECTION-ANALYSIS, Electroanalysis, 8(11), 1996, pp. 1051-1054
A sequential flow injection method for simultaneous chloride and fluor
ide determination in waters with potentiometric detection is described
. The method is based on the simultaneous chloride and fluoride potent
iometric detection using two ion selective electrodes in two serial fl
ow-through cells. The necessary ionic strength adjustment is obtained
by mixing the TISAB solution with the sample by diffusion during the p
ropelling process to the detection cells. The new method was applied s
uccessfully to drinking water samples.