The efficiency of grating coupling of radiation into the quantum well
infrared detector is studied experimentally, with special emphasis on
the influence of detector mesa size. It is found that compared to a 45
-degrees polished edge detector, the integrated quantum efficiency for
crossed grating detectors of mesa size as small as 45 mum is about fo
ur times larger with a waveguide included, and two times larger withou
t a waveguide. Furthermore, the importance of a high conductivity grat
ing metal, the use of crossed gratings instead of lamellar gratings, a
s well as of a dielectric reflector is demonstrated. To show the super
ior coupling efficiency, the detectivity is measured for a detector wi
th a crossed grating and a waveguide, and of mesa size 500 mum, result
ing in D = 1.4 x 10(11) cm Hz1/2 W-1 at 77 K operating temperature wi
th the detector shielded from background radiation.