The authors report on a technique for the treatment of congenital loba
r emphysema in a patient of 6.5 kg body weight. After left thoracotomy
and vessel isolation, a section of the lobar bronchus and interlobar
fissure was performed, because of incompleteness for 3/4 Of its length
. Metal clips were used with the stapler ENDO-GIA 30v Autosuture after
tissue calibration. The authors underline the importance of the stapl
ers, which have been widely used in adult surgery, because they reduce
the risk of bacterial contamination and air leakage through the sutur
e rims, especially in lung resective surgery.