ENHANCEMENT OF COLOR DOPPLER SIGNALS BY C ONTRAST AGENTS FOR THE ASSESSMENT OF BREAST-LESIONS

Citation
H. Madjar et al., ENHANCEMENT OF COLOR DOPPLER SIGNALS BY C ONTRAST AGENTS FOR THE ASSESSMENT OF BREAST-LESIONS, Geburtshilfe und Frauenheilkunde, 53(12), 1993, pp. 866-869
Citations number
12
Categorie Soggetti
Obsetric & Gynecology
ISSN journal
00165751
Volume
53
Issue
12
Year of publication
1993
Pages
866 - 869
Database
ISI
SICI code
0016-5751(1993)53:12<866:EOCDSB>2.0.ZU;2-R
Abstract
Doppler blood flow measurements allow differentiation of malignant les ions, that are characterised by an abnormal vascularity. The accuracy of this method is limited due to the physiological flow variation in n ormal breast parenchyma and in tumours. Magnetic resonance imaging in combination with contrast agents can also be used for flow assessment by measurement of the dynamic contrast enhancement. Recently, a new ec ho contrast agent (Levovist(R)) has been developed, which survives pul monary transit and increases the Doppler signal intensity after intrav enous injection. Fourteen malignancies with low vascularity were selec ted for the study. Twenty-two seconds after injection of contrast agen t, the Doppler signal intensity increased dramatically. This demonstra tes, that echo contrast agents might improve the diagnosis of breast l esions in case of non-conclusive Doppler findings.