A comparison of passive cooling techniques Of a non-airconditioned apa
rtment for Delhi climate condition has been presented. The various coo
ling techniques namely, evaporative cooling, movable canvas, roof gard
ens, shading effect and air cavity in walls etc. have been incorporate
d in the thermal analysis. Numerical computations were carried out for
Delhi climatic conditions and it is inferred that (i) the evaporative
cooling is the best option to reduce the incoming heat flux through t
he roof if the water is easily available, and (ii) the air cavity also
reduces the incoming flux entering through walls.