CYCLIC BEHAVIOR OF HIGH-STRENGTH CONCRETE SHORT BEAMS WITH LOWER AMOUNT OF FLEXURAL REINFORCEMENT

Citation
Ik. Fang et al., CYCLIC BEHAVIOR OF HIGH-STRENGTH CONCRETE SHORT BEAMS WITH LOWER AMOUNT OF FLEXURAL REINFORCEMENT, ACI structural journal, 91(1), 1994, pp. 10-18
Citations number
12
Categorie Soggetti
Construcion & Building Technology","Material Science
Journal title
ISSN journal
08893241
Volume
91
Issue
1
Year of publication
1994
Pages
10 - 18
Database
ISI
SICI code
0889-3241(1994)91:1<10:CBOHCS>2.0.ZU;2-P
Abstract
Experimental investigation of the cyclic behavior of high-strength con crete (HSC) short beams with lower flexural reinforcement ratio is rep orted Fifteen cantilever beam specimens were subjected to monotonic lo ading and various types of cyclic loadings. The main variables include d shear span-to-depth ratio, compressive strength of concrete, and loa ding histories. The compressive strength of concrete varied from 32 MP a (4500 psi) to 70 MPa (10,000 psi). Test results indicated that the d isplacement ductility factor of HSC short beams with lower amount of f lexural reinforcement is about 5 to 6. The trend of degradation in str ength and stiffness, as well as the energy dissipation capacity of bea m specimens, became more pronounced as the shear stress level in the p lastic hinge region increased.