COMPARATIVE PERFORMANCE OF OPEN AND TOTALLY ENCLOSED MACHINES

Citation
A. Mesrobian et Ja. Hudson, COMPARATIVE PERFORMANCE OF OPEN AND TOTALLY ENCLOSED MACHINES, IEEE transactions on industry applications, 33(1), 1997, pp. 154-159
Citations number
11
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
33
Issue
1
Year of publication
1997
Pages
154 - 159
Database
ISI
SICI code
0093-9994(1997)33:1<154:CPOOAT>2.0.ZU;2-G
Abstract
Continuous improvements in insulating materials, manufacturing consist encies in sealed windings, and extensive laboratory testing of various systems show that synchronous machines with NEMA II construction can replace totally enclosed machines, Tests on windings in corrosive atmo sphere show that sealed insulation systems are impervious to the envir onment. Standard maintenance ensures that incendive arcing will not be generated in potentially hazardous environments. When compared to tot ally enclosed machines, the NEMA II-type construction is lighter, more efficient, has lower short-circuit current and associated torques, an d is easier to maintain.