We have meaSured densities of surface charge of hepatocyte nuclei duri
ng hydrocortison induction and activation induced with amino acids mix
ture. The value of single nucleus charge, calculated from the value of
charge density, changes more during both forms of induction, that the
value of the electrokinetic potential. Thus the former better charact
erises the electrokinetic properties of nuclei during their functional
swelling.