COMPARISON OF ELECTROMAGNETIC ABSORBER USED IN ANECHOIC AND SEMIANECHOIC CHAMBERS FOR EMISSIONS AND IMMUNITY TESTING OF DIGITAL DEVICES

Citation
Cl. Holloway et al., COMPARISON OF ELECTROMAGNETIC ABSORBER USED IN ANECHOIC AND SEMIANECHOIC CHAMBERS FOR EMISSIONS AND IMMUNITY TESTING OF DIGITAL DEVICES, IEEE transactions on electromagnetic compatibility, 39(1), 1997, pp. 33-47
Citations number
57
Categorie Soggetti
Telecommunications,"Engineering, Eletrical & Electronic
ISSN journal
00189375
Volume
39
Issue
1
Year of publication
1997
Pages
33 - 47
Database
ISI
SICI code
0018-9375(1997)39:1<33:COEAUI>2.0.ZU;2-5
Abstract
The absorber used in anechoic and semi-anechoic chambers employed for emissions and immunity testing of digital devices is examined, Using r eflectivities obtained by the method of homogenization, the advantages and disadvantages of urethane pyramids, twisted-pyramids, wedges, as well as ferrite tiles, ferrite grids, and ''hybrid'' combinations of u rethanes and ferrites, are determined. General reflectivity guidelines are also presented for comparing absorber used for the electromagneti c compatibility (EMC) testing of digital devices from 30 to 1000 MHz.