A fiber-optic radiometric system based on IR AgBrxCl1-x fiber was deve
loped and different nonuniform temperature distributions have been inv
estigated. Experimental results show agreement with the theoretical mo
del. The developed system enables us to monitor nonuniform surface tem
perature distribution with an accuracy of delta T = +/- 0.1 degrees C.