J. Guena et al., DIFFERENTIAL-MODE ATOMIC POLARIMETRY WITH PULSED LASERS - HIGH-PRECISION ZERO ADJUSTMENT, Journal of the Optical Society of America. B, Optical physics, 14(2), 1997, pp. 271-284
We discuss the precise zero adjustment of a balanced differential-mode
polarimeter containing an atomic sample for dark-field detection of a
small atomic parity-violation anisotropy odd under reversal of an app
lied E field. Our sample is endowed within E-even parity-conserving an
isotropy, possibly large, but oriented to produce no imbalance. An imb
alance arises both from defects in the preparation of the sample and f
rom small probe-beam anisotropies coupling with those of the sample. A
n adjustment procedure allows identification and reduction of each def
ect. The residual E-even imbalance is maintained at the noise level by
active compensation. (C) 1997 Optical Society of America.