A CLARKSONS SECTOR INTEGRATION ROUTINE FOR PERSONAL COMPUTERS

Citation
Kd. Steidley et al., A CLARKSONS SECTOR INTEGRATION ROUTINE FOR PERSONAL COMPUTERS, Medical physics, 21(1), 1994, pp. 61-64
Citations number
17
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
Journal title
ISSN journal
00942405
Volume
21
Issue
1
Year of publication
1994
Pages
61 - 64
Database
ISI
SICI code
0094-2405(1994)21:1<61:ACSIRF>2.0.ZU;2-T
Abstract
A Clarkson's sector integration scheme has been implemented on a perso nal computer to calculate mean scatter-air ratio ((SAR) over bar) and mean tissue-air ratio ((TAR) over bar) for external photon beams of ir regular shape. To find where a given radial line from the point of int erest intersects the edge of the radiation field, polygon clipping alg orithms have been adapted from the field of image processing. The prog ram has calculation run times of similar to 1 s on an 80387 with a mat h coprocessor for an integration of 36 sectors. The software was valid ated by comparison to program IRREG, where for various squares and cli nical shapes, the agreement was typically 0.7%. The source code is ava ilable from the authors.