POOR-QUALITY RED-BLOOD-CELL LABELING WITH TC-99M - CASE-REPORT AND REVIEW OF THE LITERATURE

Authors
Citation
I. Adalet et S. Cantez, POOR-QUALITY RED-BLOOD-CELL LABELING WITH TC-99M - CASE-REPORT AND REVIEW OF THE LITERATURE, European journal of nuclear medicine, 21(2), 1994, pp. 173-175
Citations number
16
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
03406997
Volume
21
Issue
2
Year of publication
1994
Pages
173 - 175
Database
ISI
SICI code
0340-6997(1994)21:2<173:PRLWT->2.0.ZU;2-T
Abstract
Technetium-99m red blood cell (RBC) venography is a simple and sensiti ve technique for the diagnosis of deep vein thrombosis of the lower li mb, but optimal labelling of the blood pool is essential for a diagnos tic study. Here we report the case of a 44-year-old male with deep vei n thrombosis of the right leg. RBC venography of the lower extremities showed poor labelling. In addition we review the literature on the su bject.