HEMT BASED INTEGRATED CHARGE PREAMPLIFIER FIRST RESULTS

Citation
G. Bertuccio et al., HEMT BASED INTEGRATED CHARGE PREAMPLIFIER FIRST RESULTS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 338(2-3), 1994, pp. 582-584
Citations number
7
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
338
Issue
2-3
Year of publication
1994
Pages
582 - 584
Database
ISI
SICI code
0168-9002(1994)338:2-3<582:HBICPF>2.0.ZU;2-E
Abstract
The new high luminosity accelerators and the objectives of the related high energy physics experiments pose severe requirements to both dete ctors and readout electronics [1,2]. A new generation of high speed fr ont end electronics and signal processors has to be developed. In this perspective, we are presenting here an integrated charge preamplifier fully based on high electron mobility transistors (HEMT), mainly inte nded for semiconductor vertex detectors.