FLUORESCENT MICROTITER SCREENING ASSAY FOR IMMUNOCYTOCHEMICALLY REACTIVE ANTIBODIES

Citation
Jl. Su et al., FLUORESCENT MICROTITER SCREENING ASSAY FOR IMMUNOCYTOCHEMICALLY REACTIVE ANTIBODIES, BioTechniques, 22(2), 1997, pp. 320-324
Citations number
7
Categorie Soggetti
Biochemical Research Methods
Journal title
ISSN journal
07366205
Volume
22
Issue
2
Year of publication
1997
Pages
320 - 324
Database
ISI
SICI code
0736-6205(1997)22:2<320:FMSAFI>2.0.ZU;2-9
Abstract
We have developed a rapid in situ screening procedure that enables pre -screening of hundreds of hybridomas in a 96-well format. The procedur e involves fluorescence immunostaining of cells cultured in 96-well pl ates and the use of a fluorescence plate reader to detect reactive ant ibodies. Positive immunostaining in individual wells, as denoted by el evated readings, is then confirmed by fluorescence microscopy. Using t he method described here, we have successfully identified monoclonal a ntibodies that are specific to the nuclear receptor, peroxisome prolif erator-activated receptor gamma (PPAR gamma). This assay is readily ap plicable for screening hybridomas raised against to aid in the initial identification of antibodies reactive in immunocytochemical procedure s.