SIZING LARGE HOLLOW MICRO-BALLOONS WITH THE PHASE DOPPLER INTERFEROMETER

Citation
Sv. Sankar et al., SIZING LARGE HOLLOW MICRO-BALLOONS WITH THE PHASE DOPPLER INTERFEROMETER, Particle & particle systems characterization, 10(6), 1993, pp. 321-331
Citations number
11
Categorie Soggetti
Materials Science, Characterization & Testing","Engineering, Chemical
ISSN journal
09340866
Volume
10
Issue
6
Year of publication
1993
Pages
321 - 331
Database
ISI
SICI code
0934-0866(1993)10:6<321:SLHMWT>2.0.ZU;2-3
Abstract
A combined theoretical and experimental study has been conducted to ev aluate the effectiveness of using large, hollow micro-balloons as LDV seed particles. The study has focused on the ability of phase Doppler systems to size hollow micro-balloons, the ability of large micro-ball oons to respond to high frequency spatial and temporal flow field vari ations, and the overall advantages and disadvantages of using large mi cro-balloons instead of conventional LDV seed particles, such as very small water droplets or polystyrene latex (PSL) particles. This paper discusses the development of a theoretical phase Doppler response mode l for stratified spheres, the experimental facility, and the theoretic al and experimental results.