EVALUATION OF AN AUTOMATED IMMUNODIAGNOSTIC ASSAY, VIDAS ROTAVIRUS, FOR DETECTION OF ROTAVIRUS IN FECAL SPECIMENS

Citation
Ph. Dennehy et al., EVALUATION OF AN AUTOMATED IMMUNODIAGNOSTIC ASSAY, VIDAS ROTAVIRUS, FOR DETECTION OF ROTAVIRUS IN FECAL SPECIMENS, Journal of clinical microbiology, 32(3), 1994, pp. 825-827
Citations number
15
Categorie Soggetti
Microbiology
ISSN journal
00951137
Volume
32
Issue
3
Year of publication
1994
Pages
825 - 827
Database
ISI
SICI code
0095-1137(1994)32:3<825:EOAAIA>2.0.ZU;2-O
Abstract
Four hundred sixty-four fecal specimens were tested for rotavirus by t hree immunoassays, VIDAS Rotavirus (bioMerieux Vitek, Hazelwood, Mo.), Rotaclone (Cambridge Biotech Corporation, Worcester, Mass.), and Path finder Rotavirus (Sansfi Diagnostics Pasteur, Chaska, Minn.). Twenty-s even discordant specimens were evaluated by electron microscopy. The s ensitivities, specificities, positive predictive values, and negative predictive values were 98, 99.3, 98.7, and 99%, respectively, for VIDA S Rotavirus; 100, 99, 98.1, and 100%, respectively, for Rotaclone; and 100, 92.4, 87.3, and 100%, respectively for Pathfinder Rotavirus.