Vi. Sharando et Sa. Novikov, THERMOELECTRIC INSPECTION OF THE DIFFUSION ZONE AT THE COATING-BASE INTERFACE, Russian journal of nondestructive testing, 29(6), 1993, pp. 429-432
The dependence of the thermal electromotive force of a mounted transdu
cer on the annealing temperature of (e)lectroplated nickel coatings on
a base of bronze Br Kh08 was investigated experimentally. It is shown
that heat treatment can cause a multiple change in the value of the s
ignal being measured. The data obtained were compared with the reading
s of a thickness gauge having magnetic separation action and the relat
ion to the width of the diffusion zone was analyzed. The possibility o
f two-parameter inspection is discussed.