BOILING HEAT-TRANSFER OF A TERNARY REFRIGERANT MIXTURE INSIDE A HORIZONTAL SMOOTH TUBE

Citation
Ls. Zhang et al., BOILING HEAT-TRANSFER OF A TERNARY REFRIGERANT MIXTURE INSIDE A HORIZONTAL SMOOTH TUBE, International journal of heat and mass transfer, 40(9), 1997, pp. 2009-2017
Citations number
19
Categorie Soggetti
Mechanics,"Engineering, Mechanical",Thermodynamics
ISSN journal
00179310
Volume
40
Issue
9
Year of publication
1997
Pages
2009 - 2017
Database
ISI
SICI code
0017-9310(1997)40:9<2009:BHOATR>2.0.ZU;2-C
Abstract
A theoretical model for predicting the forced convective boiling heat transfer coefficients of ternary mixtures is presented. The effect of mass diffusion near the gas-liquid interface is considered in both nuc leate boiling and forced convection vaporization contributions. The pr edicted heat transfer coefficients are compared with experimental data , which are obtained for an HFC32 : 125 : 134a (23 : 25 : 52 wt%) mixt ure inside a horizontal smooth tube 6.0 mm i.d. and 4.0 m long, and in the ranges of heat flux 10-20 kW m(-2) and of mass flux 150-400 kg m( -2) s(-1). The present predictive method shows reasonable agreement wi th the experimental data within an accuracy of +/-30%. (C) 1997 Elsevi er Science Ltd. All rights reserved.