MEASUREMENT OF SOOT AT WORKPLACES AND IN AMBIENT AIR - COMPARISON OF 2 TESTING-METHODS

Citation
Hd. Bauer et al., MEASUREMENT OF SOOT AT WORKPLACES AND IN AMBIENT AIR - COMPARISON OF 2 TESTING-METHODS, Staub, Reihhaltung der Luft, 54(2), 1994, pp. 55-57
Citations number
12
Categorie Soggetti
Environmental Sciences","Engineering, Civil","Engineering, Environmental
Journal title
ISSN journal
00390771
Volume
54
Issue
2
Year of publication
1994
Pages
55 - 57
Database
ISI
SICI code
0039-0771(1994)54:2<55:MOSAWA>2.0.ZU;2-A
Abstract
A report is given on measurements which have been carried out in order to compare two testing methods for soot concentrations in air. Sample s of fine dust were taken from ambient air and each sample was divided into two parts for further treatment in different ways. Differentiati on between elemental carbon (EC), total carbon (TC) and carbon related to organic compounds (OC) was accomplished either by thermal desorpti on or liquid extraction. A good agreement of the soot concentrations r epresented by the EC values was achieved using these two methods.