IMPLOSION OF D-2 TEMPERATURE-CONTROLLED CRYOGENIC FOAM TARGETS WITH PLASTIC ABLATORS

Citation
A. Richard et al., IMPLOSION OF D-2 TEMPERATURE-CONTROLLED CRYOGENIC FOAM TARGETS WITH PLASTIC ABLATORS, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics, 49(2), 1994, pp. 1520-1526
Citations number
19
Categorie Soggetti
Physycs, Mathematical","Phsycs, Fluid & Plasmas
ISSN journal
1063651X
Volume
49
Issue
2
Year of publication
1994
Pages
1520 - 1526
Database
ISI
SICI code
1063-651X(1994)49:2<1520:IODTCF>2.0.ZU;2-L
Abstract
The implosion hydrodynamics of temperature-controlled cryogenic deuter ium foam targets with plastic ablators is investigated. The experiment al data recorded with x-ray imaging systems are compared to a one-dime nsional (1D) simulation. The ablation front trajectories derived from x-ray streak-camera data agree with 1D simulation. However, an x-ray c ore emission is observed at an earlier time, and for a longer duration than that predicted. For the three liquid-fuel shots, the convergence ratios are, respectively, 0.4, 0.9, and 0.7 times that predicted by t he ID simulation.