A modified feed-forward control system has been operated at the Brookh
aven Accelerator Test Facility to control the phase and amplitude of t
wo high power klystron rf systems used to power a photocathode rf gun
and a traveling wave electron linac. The changes to the control algori
thm include an improved handling of cross coupling between the amplitu
de and the phase channels, an improved calibration routine that allows
for changes in the matrix elements due to the variable base-line and
improved filtering. The modifications to the software include modulari
ty, portability; and user-friendliness. Improvements to the hardware i
nclude a linearized phase and amplitude controller with de biasing for
an improved dynamic range. The feed-forward system can handle nonline
ar and noninstantaneous systems. With simultaneous regulation of two c
hannels, the phase and the amplitude fluctuations over a time span of
more than 3 mu S were reduced to less than +/- 0.2 degrees and +/- 0.2
%, from the initial +/- 2.7 degrees and +/- 1.8%, respectively. (C) 19
97 American Institute of Physics.