P. Mezin et al., MORPHOMETRIC ANALYSIS OF THE PERIPHERAL-NERVE - ADVANTAGES OF THE SEMIAUTOMATED INTERACTIVE METHOD, Journal of neuroscience methods, 51(2), 1994, pp. 163-169
A semi-automated interactive method (BIOCOM) was developed for the mor
phometric analysis of the peripheral nerve in routine histopathoiogica
l examination. The human superficial peroneal nerve was used for myeli
nated fibre measurements. The precision and reproducibility of the res
ults were validated using a manual morphometric method on a digitalizi
ng table. Having compared the two methods, we believe that the semi-au
tomated method constitutes an interesting alternative to traditional m
ethods.