IMPROVEMENT OF THE ACCURACY OF THE ATOMIC TIME-SCALE AT COMMUNICATIONS-RESEARCH-LABORATORY

Citation
M. Shibuki et al., IMPROVEMENT OF THE ACCURACY OF THE ATOMIC TIME-SCALE AT COMMUNICATIONS-RESEARCH-LABORATORY, JPN J A P 1, 33(3B), 1994, pp. 1687-1690
Citations number
6
Categorie Soggetti
Physics, Applied
Volume
33
Issue
3B
Year of publication
1994
Pages
1687 - 1690
Database
ISI
SICI code
Abstract
We show the results of computer simulations of the time scale generate d by the atomic time (TA) algorithm, using data obtained from an ensem ble of clocks at Communications Research Laboratory (CRL). Three accur acy evaluations were made using the laboratory type primary frequency standard (CRL Cs1) over the period between February, 1989 and January, 1992. Our results show that the accuracy of the TA(CRL) time scale ra te is increased by more than 5-6 times when using the clock data calib rated by the primary frequency standard.