Aa. Varfolomeev et al., UNDULATOR MAGNETIC-FIELD MEASUREMENTS WITH THE WIRE DEFLECTION METHOD, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 341(1-3), 1994, pp. 470-472
A pulsed wire system was constructed and used for undulator magnetic f
ield measurements. The use of a novel type of optical detector signifi
cantly simplifies the system. Results of magnetic field measurements o
btained with the pulsed wire method and with Hall probes are compared,
and the high accuracy obtainable with the system is demonstrated.