A new modification of the Frazier-thermal-diffusion system in which co
lumn length varies by a constant increment is proposed. Equations for
estimating the most optimal column-length increment and column number
corresponding to a maximum degree of separation are derived. It is fou
nd that by adopting the present modification, substantial improvement
in performance over the classical Frazier scheme may be achieved.