INDIVIDUAL MONITORING AND ITS QUALITY ASSURANCE USING THERMOLUMINESCENT CASO4DY TEFLON TAPE DOSIMETERS IN INDIA

Citation
Js. Nagpal et al., INDIVIDUAL MONITORING AND ITS QUALITY ASSURANCE USING THERMOLUMINESCENT CASO4DY TEFLON TAPE DOSIMETERS IN INDIA, Radiation protection dosimetry, 51(4), 1994, pp. 275-282
Citations number
NO
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging","Nuclear Sciences & Tecnology
ISSN journal
01448420
Volume
51
Issue
4
Year of publication
1994
Pages
275 - 282
Database
ISI
SICI code
0144-8420(1994)51:4<275:IMAIQA>2.0.ZU;2-7
Abstract
CaSO4:Dy Teflon thermoluminscence dosemeters have been fabricated indi genously in continuous tape form. TL response of the tape dosemeters t o beta and gamma radiations has been studied as a function of the dose meter thickness to arrive at its optimum value. A single 80 mg.cm-2 th ick tape dosemeter (51 nun x 17 mm) along with a mica strip replaces t he earlier use of three 200 mg.cm-2 thick disc dosemeters for routine individual monitoring. The tape cards have been in field use for two a nd a half years. The performance characteristics of the cards under la boratory and field conditions are discussed. Dose computation algorith ms have been developed to give whole-body dose (mGy) and skin dose (mG y) for photons and beta radiation respectively from the TL outputs of three dosimetric elements under 1000 mg.cm-2 Cu+Al composite filter, 1 80 mg.cm-2 Perspex and an open region in a cardholder. Results of the Quality Assurance Programme, covering various TL monitoring stations i n India, are also presented. Based on ANSI criteria, only one outlier was observed over the past seven years.