INTEGRAL TESTING OF THE AP600 PASSIVE EMERGENCY CORE COOLING SYSTEMS

Citation
Le. Hochreiter et al., INTEGRAL TESTING OF THE AP600 PASSIVE EMERGENCY CORE COOLING SYSTEMS, Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy, 207(A4), 1993, pp. 259-268
Citations number
NO
Categorie Soggetti
Engineering, Mechanical
ISSN journal
09576509
Volume
207
Issue
A4
Year of publication
1993
Pages
259 - 268
Database
ISI
SICI code
0957-6509(1993)207:A4<259:ITOTAP>2.0.ZU;2-P
Abstract
In support of the development of AP600, Westinghouse is conducting two integral systems tests to examine the performance of the passive safe ty systems. A full-height, full-pressure test is being performed to si mulate a small loss-of-coolant, steam generator tube rupture and large steam line break events. A one-quarter scale, low-pressure test is be ing performed to simulate transients with emphasis on the transition t o the natural circulation post-accident, long-term cooling mode and to demonstrate the long-term cooling capability. Each of the tests will provide detailed experimental results for verification of the accident analysis computer codes.