Le. Hochreiter et al., INTEGRAL TESTING OF THE AP600 PASSIVE EMERGENCY CORE COOLING SYSTEMS, Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy, 207(A4), 1993, pp. 259-268
In support of the development of AP600, Westinghouse is conducting two
integral systems tests to examine the performance of the passive safe
ty systems. A full-height, full-pressure test is being performed to si
mulate a small loss-of-coolant, steam generator tube rupture and large
steam line break events. A one-quarter scale, low-pressure test is be
ing performed to simulate transients with emphasis on the transition t
o the natural circulation post-accident, long-term cooling mode and to
demonstrate the long-term cooling capability. Each of the tests will
provide detailed experimental results for verification of the accident
analysis computer codes.