Rp. Lyon et al., MONITORING OF BODY-WEIGHT DURING TRANSURETHRAL RESECTION OF THE PROSTATE - PRELIMINARY-REPORT, Journal of endourology, 8(2), 1994, pp. 161-163
The fear of vascular overload by irrigant during transurethral resecti
on of the prostate is a reason for an incomplete resection. With conti
nuous measurement of the patient's body weight and, thus, body water,
irrigant entrance is immediately identified. We present a scale of pro
ved accuracy and reliability, allowing more effective resection while
eliminating the possibility of TUR syndrome.